The combination storage Stove Toulouse S provides soothing radiant heat for many hours thanks to its solid natural stone cladding. The Stove can be operated either with firewood or with our electricity-free Pellet System Inserts KO2 S and KO2 XL. Additionally, the Stove can be optionally equipped with an extra 40 kg storage block.
Toulouse S, Stove with natural stone
Data and facts
Technical data
| measurements (cm) | H x W x D 116 x 61,5 x 48,5 cm |
| combustion chamber | H x W x D 30 x 37 x 29 cm |
| fire glass | H x W 42 x 34 cm |
| fire door | H x W 53 x 45 cm |
| total weight | 253 kg |
| chamotte bricks | 26 kg |
Data for firewood
| nominal heat output | 7,9 kW |
| efficiency | 81 % |
| heating capability | 70 - 250 m³ |
| amount of fuel | 2,48 kg / h |
| fire duration | up to 5 h |
| heat release | up to 13 h |
| flue gas flow volume | 8,45 g/s |
| exhaust °C (nozzle) | 265 °C |
| min/max feed press. | 12 / 15 Pa |
| CO (13%O2) | ≤ 1250 mg/m³ |
| dust (13%/O2) [mg/m³] | ≤ 40 mg/m³ |
| NOx (13%O2) | ≤ 200 mg/m³ |
| OGC (CxHy) (13%O2) | ≤ 120 mg/m³ |
Data for Pellet System Insert KO2 S
| nominal heat output | 7,5 kW |
| output range | 7,5 - 5 kW |
| efficiency | 87% |
| heating capability | 50 - 150m³ |
| amount of fuel | 3,8 kg |
| fire duration | up to 2,5 h |
| heat release | up to 10 h |
| flue gas flow volume | 8,97 g/s |
| exhaust °C (nozzle) | 180 °C |
| min/max feed press. | 12 / 15 Pa |
| CO (13%O2) | 1166 mg/m³ |
| CO (13%O2) | 0,093 % |
| dust (13%/O2) [mg/m³] | 36 mg/m³ |
| NOx (13%O2) | 109 mg/m³ |
| OGC (CxHy) (13%O2) | 54 mg/m³ |
Data for Pellet System Insert KO2 XL
| nominal heat output | 11 kW |
| output range | 11 - 8,5 kW |
| efficiency | 85% |
| heating capability | 70 - 250 m³ |
| amount of fuel | 7,5 kg |
| fire duration | up to 5 h |
| heat release | up to 13 h |
| flue gas flow volume | 10,74 g/s |
| exhaust °C (nozzle) | 230 °C |
| min/max feed press. | 12 / 15 Pa |
| CO (13%O2) | 880 mg/m³ |
| CO (13%O2) | 0,070 % |
| dust (13%/O2) [mg/m³] | 30 mg/m³ |
| NOx (13%O2) | 110 mg/m³ |
| OGC (CxHy) (13%O2) | 41 mg/m³ |
Distances to combustible walls / components
| wall distance, rear | 30 cm |
| wall distance, side | 20 cm |
| distance to the front | 100 cm |
- Flue pipe connection Ø 15 upwards ↑
- Outside air connection Ø 10 horizontal → or vertical ↓ possible (Please specify when ordering)
Compatible pellet system inserts
Accessories
- Stainless Steel Floor Protection
- Glas Floor Protection
- Heat Accumulation Block(2 parts, 40 kg)
Downloads
ARRAY